Item 5388 - Burner & Gas Train Lo-NOx 100 MMBTU
Manufacturer
Nat-Com
Model
P-96-G-23-1118
Capacity
100

National Combustion Equipment (Nat-Com) Lo-Nox burner. Natural gas, sn 10755. Operating energy 83 MMBTU output. (Max is approx 100 MMBTU). Burner model P-96-G-23-1118, gas heater model GH-90-120-128-226, Includes gas train and fire management system. See links for burner drawing and gas train skid drawing. Gas train skid size 135" long x 31" deep x 86" tall (includes all valves and control panel) Used as Ring Dryer Burner. Ser no. 10755-GH. See gas train drawing in Links. Not sold separately at this time.

Place Holder
Item VK-2024 - Burner & Gas Train Lo-NOx 100 MMBTU
Manufacturer
Nat-Com
Model
P-96-G-23-1118
Capacity
83

National Combustion Equipment (Nat-Com) Lo-NOx burner. Natural gas, sn 10815. Operating energy 83 MMBTU output. (Max is approx 100 MMBTU). Burner model P-96-G-23-1118, gas heater model GH-90-120-128-226, Includes gas train and fire management system. See links for burner drawing and gas train skid drawing. Gas train skid size 135" long x 31" deep x 86" tall (includes all valves and control panel) Used as Ring Dryer Burner. Part of ring dryer DR-5210, not sold separately at this time. For a list of components and their photos & description enter dr5201 in search box on web site

Place Holder
Item 5387 - Burner and Gas Train
Manufacturer
Model
.

Burner & Gas Train. This is currently not being sold separately - is a part of the RTO asset # PK-5429 Not avaialble until late Summer.

Place Holder
Item FH-9141 - Coal Combustor
Manufacturer
EPI (Outotec Energy)
Model
.
Capacity
289

EPI coal combustor - now Outotec Energy Products. Physical size approx 20 ft x 32 ft. x 84 ft tall Steel weight takeoff from drawing = 578,144 pounds. Designed to burn coal slurry (dried coal "powder" ) from coal wash pits. Rate of coal slurry 23,585 lb/hr. The entire system is available, however, we will sell equipment individually. See Simplified Flow Chart in Links for a pictorial of each piece in this system. For a list of all components, enter PK9140 in the search box

Place Holder
Item 7176 - Deaerator
Manufacturer
PMI Industries
Model
Capacity
28000

Deaerator for water feed to steam system. Mfg by PMI Industries, made by Hall Tank. Spray tray design for 28,000 #/hr steam. ASME Nat'l Bd #95 MAWP 50 psi at 500F. Serial # 126-861. Size approx 3 ft 6 in dia x 10 ft s/s x 11 ft OAL x 8 ft 6 in OAH. Dry weight 3000 pounds. See multi-page drawing for more details

Place Holder
Item Z-7202C - Deaerator
Manufacturer
Superior
Model
TC150T135-100
Capacity
150000

Deaerator system mfg by Superior. Superior Triplex Tray Deaerator Model TC150T135-100. ASME certified and stamped. Designed for 150,000 #/hr, pressure 50 psig at 400F, deaerator capacity 3,075 gallons. Mat'l cs SA-516-70. Horizontal tank 84" OD x 13.75 ft OAL. Vertical deaerator tank on top is 72" OD x 9.25 OAH. Both sit in a structures with (3) Grundfos feedwater pumps. Dimensions of complete deaerator structure are approx 100" x 116" x 329" tall OAH. Includes all attached instrumentation, valving and piping manifolds. There are 3 Grundfos pumps at 30HP, Type CR45-4-2K-G-A-E-KUHE, Model A966.37616-P10713022. Each designed for 237 gpm at 341 ft TDH, 4 stage driven by 30HP motor 460/3/60. Complete system weight 18,000 pounds empty. See drawing in Links for details.

Place Holder
Item 6922 - Dowtherm Vaporizer 5MMBTU
Manufacturer
First Thermal
Model
5 MMBTU
Capacity
5

IC First Thermal (Eclipse) Dowtherm firetube vaporizer, capacity 5 MMBTU at 135 psig. Burns natural gas, has 5 HP motor fan blower. Built in 1975, Serial number 44910, ASME Nat'l Bd# 41254. Repaired in 2004 by Industrial Boiler and Mechanical (Chattanooga). Physical size is approximately 6 ft dia x 12 ft long + blower section. Currently vaporizes Dowtherm but can be converted into a Thermal Fluid Heater for use with such oil heater products as food safe MobilTherm. See manufacturer's data report in links. The manufacturer is still in business and supports this vaporizer. Was in operation until February 2013. Removed and ready to load.

Place Holder
Item EC-9141 - Economizer
Manufacturer
Rentech
Model
.
Capacity
35

Economizer for Rentech Combustor boiler. Designed for 25.28 MMBTU. Weight takeoff 70,000 pounds. Sprayed on internal refractory. The entire system is available, however, we will sell equipment individually. See Simplified Flow Chart in Links for a pictorial of each piece in this system. For a list of all components, enter PK9140 in the search box

Item 8096 - Firetube Boiler 200HP
Manufacturer
Johnston
Model
Capacity
200

One (1) 1998 200 HP Johnston boiler, 4 pass wet back, gas and No. 2 oil fired, 250 PSI design pressure The boiler will be cleaned on the fireside, waterside, outside, and painted. The boiler pressure vessel, tubes, piping, and blowdown valves will be hydrostatically tested. The existing Honeywell 7800L Flame Safeguard Controls will be checked and replaced if found defective. New Honeywell High Limit with manual reset, Operating Limit, and Modulating Limit Controls will be installed. The boiler will be electrically and mechanically checked throughout to identify and replace any defective components. The combustion air fan will be run to check for balance and bearing smoothness. We guarantee that the pressure vessel and tubes are in good condition and that the boiler will pass a hydrostatic test at the time of startup. We will give a 1 year parts replacement warranty on controls. These photos are representative - boiler is yet to be reconditioned - allow 4 to 6 weeks after order. This quote is for the boiler only. No support equipment is included. Note that this boiler is a litle shorter and wider than standard Johnston dimensions so will not be a direct drop in if replacing with like kind.

Place Holder
Item Z-7201A - Firetube Boiler 2200 HP Lo NOx
Manufacturer
Superior
Model
8-X-11000-S150-GPCF-G
Capacity
2200

Firetube Boiler, Superior Boiler and Economizer 2200HP (73,645 MBTU) steam OUT, natural gas fired 150 psig. Superior Apache 2-Pass Dryback Scotch Marine Package Boiler Model 8-X-11000-S150-GPCF-G. Natural gas firing rate IN 92,400 cfh of 1000 BTU/cf. ASME Nat'l Bd# 16198. A Cleaver Brooks Lo NOx < 30 ppm and 0.0364 lbs. per MMBTU burner was installed in 2015, Model LNXLG-924, serial 58734-1. Includes controls and firing monitoring, gas train, forced draft blower, Kunkle safety valves 6x8" and 4x6" both set at 100 psig. Boiler dimensions are approx 151" w x 302" L x 153" tall. Approx overall floor space needed: 43.6 ft L x 19.3 ft W x 13.2 ft T (not including safety valves and economizer and stack). Cain economizer model RJR-166K26ALS. Stainless steel. Stack is Van-Packer Model DW 36" ID x 20'-9" long, ss304 insulated. See drawing and manual for verification. Weight empty approx 121,000 pounds. Idled 2018. This boiler has been mothballed properly, and is in supervised dry storage with "VpCI" (vapor phase corrosion inhibitor). It was just checked again by the third party in early 2020

Place Holder
Item Z-7201B - FIretube Boiler 2200 HP Lo NOx
Manufacturer
Superior
Model
8-X-11000-S150-GPCF-G
Capacity
2200

Firetube Boiler, Superior Boiler and Economizer 2200HP (73,645 MBTU) steam OUT, Lo NOx natural gas fired 150 psig. Superior Apache 2-Pass Dryback Scotch Marine Package Boiler Model 8-X-11000-S150-GPCF-G. Natural gas firing rate IN 92,400 cfh of 1000 BTU/cf. ASME Nat'l Bd# 16199. Cleaver Brooks burner model LNXLG-924. Lo NOx < 30 ppm and 0.0364 lbs. per MMBTU. Includes controls and firing monitoring, gas train, forced draft blower, Kunkle safety valves 6x8" and 4x6" both set at 100 psig. Boiler dimensions are approx 151" w x 302" L x 153" tall. Approx floor space needed: 43.6 ft L x 19.3 ft W x 13.2 ft T (not including safety valves and economizer and stack). Cain economizer model RJR-166K26ALS. Stainless steel. Stack is Van-Packer Model DW 36" ID x 20'-9" long, ss304 insulated. See drawing and manual for verification. Weight empty approx 121,000 pounds. Idled 2018. This boiler has been mothballed properly, and is in supervised dry storage with "VpCI" (vapor phase corrosion inhibitor). It was just checked again by the third party in early 2020.

Place Holder
Item Z-7201C - Firetube Boiler 2200HP
Manufacturer
Superior
Model
8-5-11000-S150
Capacity
2200

Superior fire tube boiler 2200 HP (76,000 #/hr). Model 8-5-11000-S150, Boiler serial numbers 16210 and 16202. ASME NB# 16210 & xxxxx. Steam pressure 150 psig, Natural gas fired, Webster burners. Webster model HDRSX-RF-G-92-1500-SL-MK6-M.40VGD-NFPA-85. Serial no. 83593A-01 and 83593B-01. Max firing 92,050 MBTY.H, min at 11506 MBTUH. Includes economizer & stack. Boilers are left hand and right hand. Boilers are idle since 2018, drained, cleaned, dried - front and back doors open. Cain economizer and 36" ID ss stack. These boilers received daily PM's and annual PM included full inspection, cleaning, replacement of wear parts. Boiler controls are Siemens and relatively new - replaced in 2016. We also have the deaerator and feedwater pump skid for sale. See representative drawings in Links. Qty (2) available - priced separately.

Place Holder
Item 5339 - Firetube Boiler 300HP
Manufacturer
Donlee York
Model
300HP
Capacity
300

Donlee York 300HP Firetube Boiler. Model SPHV-300-N-200132. This boiler produces steam at 150 psi and runs on natural gas. Boiler has been reconditioned. Price includes loading. Built in 2000, Rebuilt in 2014. Serial: 00-21032 H-14225. The boiler does not have a water makeup tank nor a softener. The unit has been rebuilt which includes: Hydro Test and wash out to remove scale from unit, Refractory in doors and burner throat inspected and repaired as needed, the pressure tools, fire side gaskets, and water side gaskets were replaced, boiler tubes were brushed, rebuilt wind box and installed new bearings, new mod motor for the blower, new chassis for the fireye flame safe, blowdown piping and valves replaced.

Place Holder
Item 7124 - Firetube Boiler 300HP
Manufacturer
Garioni
Model
Firetube
Capacity
300

Garioni firetube boiler 300HP. Type NG5000, serial 7118. Mfg by Garioni, Brescia, Italy. Capacity 5000 kg/hr (11,000 pph steam or about 300 HP at 12 barg max (180 psig). Firetube 2-pass dry back type boiler. Built in 2002 but only used about 6 months. Electrical for controls is 110V 60 Hz. Burner fires on #2 fuel oil - pumps not included. Will need new control panel. Sold As Is - price includes loading on your truck.

Place Holder
Item 1724 - Firetube Boiler 400HP + Deaerator
Manufacturer
Hurst
Model
Scotch Marine
Capacity
400

Hurst Firetube boiler 400 HP Scotch Marine type, 4-pass wetback type. Natural gas fired, 150 psig steam. Lo NOx burner - John Zink model FRMB15.4-G-400. Generates steam at 13,800 #/hr at 150 psig. Series 500-400 HP boiler, Ser num S2000-150-85. HBC number 07-0021, ASME Nat'l Bd num 13820 built in 2007, idled 2012. Includes 2 relief valves Kunkle 2x2.5" and 1.5x2" set at 150 psig. Boiler physical size 22'-5" lomg x 110" wide x 115" tall. Deaerator 41.375" dia x 7 ft long on skid structure with (2) Grundfos boiler feedwater pumps underneath. Sn 0700022DA Nat'l Bd # 13,875 built 2007. Mat'l cs SA-516-70. See links for boiler drawing, P-2 and U1-A.

Place Holder
Item 7459 - Firetube Boiler 750HP
Manufacturer
Johnston
Model
750HP
Capacity
750

Johnston 750HP Firetube Boiler. Built in 1989. 4 pass wet-back with steam at 150psi. This boiler has an IC burner and runs on gas and #2 and #6 oil. Boiler is in good condition and so are the tubes. Price is " as is " and includes loading the boiler onto your truck. Boiler can be offered " reconditioned ". If interested, please inquire about additional reconditioned price.

Place Holder
Item GT-9150 - Flame Detection System, Boiler
Manufacturer
Diamond Power
Model
.

Flame detection system camera for boiler flame guard control. Detector on motorized extending arm. Diamond Power Scanner with auto retract. Fully supported by B&W, the original Diamond equipment manufacturer. Used as scanner on coal combustor

Place Holder
Item 7259 - Heat Recovery Boiler 800 HP
Manufacturer
Rentech
Model
.
Capacity
800

27,587 Lbs/Hr. (800 HP), 290 PSIG MAWP, RENTECH Heat Recovery Boiler, Water Tube Design with Hoppers. Year 2012. UNUSED Surplus, Never Installed. Constructed in strict accordance with ASME code Section I, 2010 edition, 2011 addenda. Stamped and registered with the national board. MAWP: 290 PSIG/FV; Hydrotest Pressure: 435 PSIG; Design Temperature 500?F (700?F TUBES); Weight: 65000 LBS (Dry) 92000 LBS (Full) 87000 LBS (Operating). Dimensions: 23'-6" L x 8'-3/4" W x 13'-3" H. Built Year 2012. Includes Hoppers, Boiler trim and Catwalks. See Drawings for more details. Available Due to Cancelled Project. This is Unused Surplus equipment in excellent condition.

Place Holder
Item BO-9141 - HRSG Boiler (from Combustor)
Manufacturer
Rentech
Model
.
Capacity
114

Rentech boiler from combustor hot air. Boiler rated at 130,000 #/hr steam at 650 psig. Crossflow watertube boiler for incoming flue gas of 273,700 #.hr at 1700F. The system also has a 2-stage superheater and 2 evaporative sections - and a separate economizer (See asset EC-9141). Steam drum on top, dims 72" ID x 16 ft long, MAWP 800 psig at 525F. . Has refractory sprayed internally. Weight takeoff from prints: Boiler weight 50,964# , transitions & structure 177,462 pounds = 228,426 pounds. Used as HRSG - Heat Recovery Steam Generator at CoGen. Boiler dimensions approximately 39'-6" long (4 sections) x 10 ft wide x 40 ft tall on 28 ft legs (68-8 OAH). See LINKS for specifications and drawings. This price is for Rentech HRSG only as described above - The entire system is available as well for sale in pieces or a whole. See Simplified Flow Chart in Links for a pictorial of each piece in this system. For a list of all components, enter PK9140 in the search box

Item ME-5201 - Stack ss 65 ft
Manufacturer
GEA Barr Rosin
Model
.
Capacity
175000

Stainless steel stack, ss 304L. Size 56" OD x 65 ft tall insulated duct. Dryer exhaust design 175,000 acfm (bleed off to RTO 63,000 acfm) Material ss 304L. Used as exhaust/dumpstack for Dryer system. Part of dryer system DR-5201, and not sold separately at this time. For a complete list of components, enter dr5201 in search box.

Place Holder
Item CEM-9101 - Stack Emissions Monitor CEMS
Manufacturer
CEM
Model
Ekto

[Note - Seller may want to keep]. CEM's instrument stack monitor - EKTO Building. Model 8812SP, 768 cubic feet. Teledyne (CEMS) Unit used for stack gas emission analyzing and transmitting with (6) rack mounted units: Nox O2 SO2 CO CO2 Sensors and plus other rack mounted units in cabinet. Climate controlled building by EKTO, Model 866sp. 288 cu ft. Includes Allen Bradley plc and touch screen. Includes everything inside the building plus the building. See Simplified Flow Chart in Links for a pictorial of each piece in this system. For a list of all components, enter PK9140 in the search box.

Place Holder
Item ME-5201C - Stack ss 65 ft
Manufacturer
GEA Barr Rosin
Model
.
Capacity
175000

Stainless steel stack, This data must be verified: size 56" OD x 65 ft tall insulated duct. Dryer exhaust design 175,000 acfm (bleed off to RTO 63,000 acfm) Material ss 304L. Used as exhaust stack for Dryer system.

Place Holder
Item ST-9101 - Stack, Stainless Steel
Manufacturer
Model
.

Stack, Stainless steel approx 6 ft dia x 100 ft. Designed for 97,290 cfm. The entire system is available, however, we will sell equipment individually. See Simplified Flow Chart in Links for a pictorial of each piece in this system. For a list of all components, enter PK9140 in the search box.

Place Holder